WhatsApp Chat with us
NDIR Gas Analyser
NDIR Gas Analyser

NDIR Gas Analyser

Price 598500 INR/ Set

MOQ : 1 Set

NDIR Gas Analyser Specification

  • Accuracy
  • +2 %
  • Voltage
  • 230 Volt (v)
  • Power Supply
  • Electric
  • Weight
  • 2.5 Kilograms (kg)
  • Usage
  • Industrial
  • Material
  • Aluminum
  • Temperature
  • 15 Celsius (oC)
  • Dimension (L*W*H)
  • 430 X 150 X 250 Millimeter (mm)
  • Humidity
  • < 85%RH
 

NDIR Gas Analyser Trade Information

  • Minimum Order Quantity
  • 1 Set
  • FOB Port
  • Mumbai
  • Supply Ability
  • 50 Sets Per Week
  • Delivery Time
  • 1-2 Week
  • Sample Policy
  • Within a certain price range free samples are available
  • Packaging Details
  • normal packing with thermocol
  • Main Domestic Market
  • All India
 

About NDIR Gas Analyser

Our company's main aim is to provide our clients across the globe pristine quality NDIR Gas Analyzer (Nondispersive Infrared Sensor). This analyzer is used to detecting the level of infra red rays. This analyzer is manufactured by utilizing ultra-modern tools and technology and quality approved components as per the instructions provided by our skilled professionals as per market norms. Our clients can purchase this NDIR Gas Analyzer from us at nominal prices within the promised time frame.

Features :-

  • Hassle-free operation
  • User-friendly design
  • Sturdy construction
  • Excellent finish
Description :-
  • Model ATS- 208A Emission Analyzer continuously monitors the concentration of gases ranging from 100%V/V down to PPM level. Feature includes a duel wavelength sensor, Remote Sampling, Graphics LCD Display, adjustable level relay output for alarm and 4-20mA output for control purpose and minimal maintenance.
  • Special gas sample Conditioning systems are used to clean and dry the gas sample for accurate and High performance operation. An Internal Pump draw gas sample into the sensor through a dust particle filter from an intake which can be located at distance up to 40 meter form the monitor.
  • The Sensor and Electronic component are housed in tough aluminium housing.

Specification :-

Principle

Electrochemical, TCD (Thermal Conductivity) , NDIR (Non Dispersive Infrared ), Zirconium and Paramagnetic

Range

%V/V, % LEL, PPM, Mg/M3

Resolution

0.1 Unit or 1 Unit (Application based)

Sampling Method

Auto Suction

Gas Sampling Probe

Dia 8mm SS 316

Display

320 X 264 Graphic LCD

Alarm

Relay Contact NO+NC

Anolog Out Put

4-20mA

Digital Out Put

RS 232, RS 485 and Modbus Comminication Protocol

Power Source

230VAC

Accuracy

+/2%

Response Time

<5 Second

Data Storage

5000 or 10000

Computer Interface

RS 232, USB, RS485

Sensor Life

2-3 Years

Environmental

 

Temperature

15degree Celsius

Humidity

< 85%RH

Atmosphere Pressure

86-   106Kpa

Dimension in mm

430 (W) X 150(H) X 250(D)

Weight

2.5 KG

Warranty

One Year



Precision in Gas Detection

Utilizing advanced NDIR technology, this analyser offers highly accurate gas detection for industrial applications. Its 2% accuracy margin ensures reliable readings, making it ideal for process monitoring and safety compliance. The device is designed for easy integration into existing systems without compromising performance.


Built for Industrial Demands

Housed in sturdy aluminum, this analyser can withstand challenging environments. The compact and lightweight design allows for easy installation and portability within industrial settings. Its operational efficiency at moderate temperatures and humidity ensures longevity and consistent performance.

FAQs of NDIR Gas Analyser:


Q: How does the NDIR Gas Analyser operate for industrial applications?

A: The analyser functions by utilizing non-dispersive infrared (NDIR) technology to detect and measure specific gases within an industrial environment, offering reliable data for safety and process optimization.

Q: What is the accuracy level of this gas analyser?

A: This gas analyser provides an accuracy of 2%, ensuring precise measurements and dependable results in various industrial uses.

Q: When should regular maintenance be performed on the NDIR Gas Analyser?

A: Regular maintenance is recommended as per the manufacturers guidelines, typically every 6 to 12 months, to ensure optimal accuracy and functionality, especially in demanding industrial environments.

Q: Where is this NDIR Gas Analyser manufactured and supplied from?

A: The analyser is manufactured, distributed, and serviced in India by a company that acts as an exporter, importer, manufacturer, service provider, and supplier.

Q: What is the installation process for this analyser in an industrial facility?

A: Installation is straightforward due to its compact dimensions and light weight. It requires a stable platform, a 230-volt power source, and environmental conditions within 15C temperature and less than 85% relative humidity.

Q: How can this analyser benefit industrial operations?

A: It increases operational safety, helps maintain process quality, and reduces downtime by providing real-time, precise gas measurement data crucial in industrial settings.

Q: What industrial environments are suitable for this analysers usage?

A: It is ideal for industries with controlled temperatures, moderate humidity, and a stable power supply, such as manufacturing plants, processing facilities, and quality control laboratories.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Gas Analysers Category

NDIR Based Gas Analyzer

NDIR Based Gas Analyzer

Price 198800 INR / Set

Minimum Order Quantity : 1 Set

Usage : Industrial

Material : Aluminium

Voltage : 230 Volt (v)

Automatic Nitrogen Purity Analyzer

Automatic Nitrogen Purity Analyzer

Price 65500 INR / Unit

Minimum Order Quantity : 1 Unit

Usage : Industrial

Material : MS

Voltage : 110215 Volt (v)

Automation Grade : Semiautomatic

ATS Portable Stack Gas Analyzer Model ATS 206A

ATS Portable Stack Gas Analyzer Model ATS 206A

Price 158000 INR / Unit

Minimum Order Quantity : 1 Unit

Usage : Industrial

Material : MS

Voltage : 110215 Volt (v)

Automation Grade : Semiautomatic

ATS-203 Turbine Gas Analyzer

ATS-203 Turbine Gas Analyzer

Price 375500 INR / Unit

Minimum Order Quantity : 1 Unit

Usage : Industrial

Material : MS

Voltage : 110215 Volt (v)

Automation Grade : Semiautomatic



Back to top