WhatsApp Chat with us
Fixed Gas Detector Transmitter
Fixed Gas Detector Transmitter
Fixed Gas Detector Transmitter
Fixed Gas Detector Transmitter
Fixed Gas Detector Transmitter
Fixed Gas Detector Transmitter

Fixed Gas Detector Transmitter

Price 25500.0 INR/ Unit

MOQ : 1 Unit

Fixed Gas Detector Transmitter Specification

  • Response Time
  • <30 Seconds (T90)
  • Spectral Range
  • 0-25% Volume (Oxygen)
  • Interface
  • Wired
  • Cable Length
  • Up to 1.5 meters (standard)
  • Housing Material
  • ABS Plastic Enclosure
  • Features
  • Digital Display, Robust Enclosure, Fast Response, Easy Installation
  • Signal Type
  • Current Output (4-20 mA)
  • Mounting Thread
  • 1 NPT
  • Operating Temperature
  • -20C to +50C
  • Application
  • Oxygen Concentration Monitoring
  • Wireless
  • No
  • Ingress Protection
  • IP65
  • Sensitivity
  • High
  • Mounting Type
  • Wall Mount / Duct Mount
  • Power Consumption
  • <2W
  • Measurement Range
  • 0-25% Vol Oxygen
  • IP Rating
  • IP65
  • Sensor Type
  • Electrochemical for Oxygen
  • Product Type
  • Fixed Gas Detector Transmitter
  • Material
  • Plastic / Polycarbonate
  • Input
  • 24V DC
  • Output
  • 4-20 mA Analog Signal
  • Function
  • Continuous Gas Level Monitoring
  • Usage
  • Industrial & Commercial Safety Applications
  • Accuracy
  • 2% of Full Scale
  • Resolution
  • 0.1 % Volume
  • Voltage
  • 24V DC (Nominal)
  • Weight
  • Approx. 350 g
  • Environmental Humidity
  • 0-95% RH Non-Condensing
  • Sensor Life
  • 2 Years (typical, for Oxygen Sensor)
  • Calibration
  • Manual, via push buttons or by supplier
  • Model
  • ATS-109TD
  • Display Type
  • 4 Digit Red LED
  • Dimensions
  • 120 x 120 x 80 mm
  • Alarm Output
  • Optional Relay (on request)
 
 

About Fixed Gas Detector Transmitter

The Gas Sensor Transmitter WP (Weatherproof) is a reliable industrial gas detection and monitoring device designed for the continuous measurement of hazardous, toxic, combustible, and flammable gases in indoor and outdoor environments. The transmitter can be configured with suitable gas sensors for detecting gases such as Oxygen (O), Hydrogen Sulfide (HS), Carbon Monoxide (CO), Sulfur Dioxide (SO), Hydrogen (H), Methane (CH), combustible gases, VOCs, and other toxic or flammable gases, depending on the application requirement. Its rugged weatherproof construction makes it suitable for demanding industrial conditions and outdoor gas monitoring applications. The transmitter provides reliable gas concentration measurement with 420 mA output, alarm/relay options, self-diagnostics, and continuous monitoring capabilities, and can be integrated with fixed gas detection and multi-point gas monitoring systems. It is suitable for gas leak detection, plant safety, process monitoring, storage area monitoring, workplace safety, and continuous gas monitoring in Oil Refineries, Petrochemical, Chemical, Oil & Gas, Natural Gas, LNG/LPG, Fertilizer, Coal Mining, Power Plants, Iron & Steel, Foundries, Pharmaceutical, Battery Manufacturing, and other industrial environments.

Precise Oxygen Level Detection

The ATS-109TD excels at monitoring oxygen concentrations ranging from 0 to 25% by volume, with high sensitivity and digital accuracy. The large red LED display ensures clear visibility, even in low-light environments, making safety checks and readings both easy and precise. The fast response time enables prompt action to potential hazards.


Rugged and Reliable Construction

Housed in a durable ABS plastic enclosure with an IP65 ingress protection rating, the ATS-109TD resists dust and water ingress, ensuring reliable operation in challenging environments. Designed for wall or duct mounting, its compact size and weight make installation straightforward, supporting rigorous industrial safety demands.


Simple Calibration and Maintenance

Calibration is performed manually via push buttons or by service personnel, ensuring the device stays accurate and trustworthy. With a sensor lifespan of around two years under typical conditions, regular maintenance routines are minimal but effective, supporting a dependable safety infrastructure in your operation.

FAQ's of Fixed Gas Detector Transmitter:


Q: How is the ATS-109TD Fixed Gas Detector Transmitter installed?

A: The ATS-109TD can be wall or duct mounted using the provided 1 NPT mounting thread. With a compact 120 x 120 x 80 mm enclosure and up to 1.5 meters of cable as standard, installation is simple and suitable for a variety of industrial or commercial settings.

Q: What is the process for calibrating this gas detector?

A: Calibration is done manually via onboard push buttons, allowing users to easily adjust the sensor on-site. Calibration services from the supplier are also available, ensuring ongoing accuracy in oxygen concentration measurements.

Q: When should the sensor be replaced?

A: The electrochemical oxygen sensor typically lasts about two years under normal operating conditions. It is recommended to replace the sensor at this interval or if the device indicates decreased sensitivity or calibration cannot be achieved.

Q: Where is the ATS-109TD typically used?

A: The ATS-109TD is designed for industrial and commercial safety applications, monitoring oxygen levels in locations such as manufacturing plants, storage facilities, laboratories, and other critical environments requiring reliable oxygen detection.

Q: What benefits does the optional relay alarm output provide?

A: When requested, the optional relay alarm output activates external devices such as alarms or ventilation systems in response to unsafe oxygen levels, enhancing safety by enabling immediate hazard response.

Q: How accurate is the ATS-109TD, and what display readability does it offer?

A: With an accuracy of 2% of full scale and a high-resolution digital display (0.1% volume increments), the ATS-109TD provides easily readable, precise oxygen measurements for effective monitoring and improved safety decisions.

Q: What power and signal output options are available?

A: The device operates on 24V DC power and outputs a 4-20 mA analog signal for integration into safety systems or data logging setups, supporting industry-standard current loop monitoring.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Gas Transmitters Category

LEL Sensor Transmitter

LEL Sensor Transmitter

Price 18900.0 INR / Piece

Minimum Order Quantity : 1 Piece

Input : Ambient Air

Operating Temperature : 10 C to +50 C Celsius (oC)

Product Type : Oxygen Sensor With Transmitter

Signal Type : Analog

Fixed Gas Sensor Transmitter

Fixed Gas Sensor Transmitter

Price 26500.0 INR / Unit

Minimum Order Quantity : 1 Unit

Input : 24V DC

Operating Temperature : 20C to +50C

Product Type : Fixed Gas Sensor Transmitter

Signal Type : Other, Analog 420 mA

Weatherproof Gas Sensor Transmitter

Weatherproof Gas Sensor Transmitter

Price 35500.0 INR / Piece

Minimum Order Quantity : 1 Piece

Input : Gas concentration (Oxygen)

Operating Temperature : 10C to +50C

Product Type : Gas Sensor Transmitter

Signal Type : Other, 420mA, RS485 Modbus

Hazardous Area Gas Transmitter

Hazardous Area Gas Transmitter

Price 22500.0 INR / Piece

Minimum Order Quantity : 1 Piece

Input : 24V DC

Operating Temperature : 20C to +60C

Product Type : Hazardous Area Gas Transmitter

Signal Type : Other, Analog 420mA



Back to top