Industrial Gas Monitoring System Specification

  • Interface
  • Push Button Control, RS-485 Data Interface
  • Connectivity Type
  • RS-485, Relay Contacts
  • Mounting Type
  • Wall Mount, Enclosure Mounting
  • License Free
  • Yes
  • Operating Mode
  • Continuous Gas Monitoring
  • Size
  • Compact Terminal Box and Main Module
  • Standard
  • Industrial Grade, Compliance with Safety Standards
  • Technology
  • Electrochemical Sensing with Digital Display
  • Special Features
  • Real-time Monitoring, Multi-status Indicator LEDs, User Programmable
  • Application
  • Industrial Gas Detection, Hazardous Area Safety Monitoring
  • Screen Resolution
  • Backlit LCD Display, Large 4-digit PPM Indicator
  • Power Supply
  • 230 VAC
  • Output Formats
  • Relay Output, RS-485 Communication
  • Display Type
  • Digital Backlit LCD
  • Sensor Connectivity
  • Dedicated Sensor Port
  • Alarm Type
  • Visual (LED) and Audible (Optional)
  • Status Indicators
  • Main, Alarm, Trouble LEDs on Front Panel
  • Reset Function
  • Manual Reset via Button
  • Control Buttons
  • FN, EN, RESET, Arrow Keys
  • Calibration
  • User Configurable
  • Gas Measured
  • NH3 (Ammonia)
  • Sensor Type
  • Electrochemical
  • Enclosure Protection
  • Weatherproof Casing
  • Operation Temperature
  • -10C to 50C
  • Terminal Box Connections
  • Sensor, RS-485, Relay, 230 VAC
  • Data Logging
  • Optional via RS-485 Interface
  • Model
  • ATS-107M
  • Installation
  • Suitable for Indoor Industrial Settings
 
 

About Industrial Gas Monitoring System

The Fixed / Continuous Gas Monitoring System is an industrial gas detection and monitoring solution designed for the continuous measurement of hazardous, toxic, combustible, and flammable gases in industrial and commercial environments. The system can be configured with multiple gas sensor transmitters and control units to continuously monitor gases such as Oxygen (O), Hydrogen Sulfide (HS), Carbon Monoxide (CO), Sulfur Dioxide (SO), Hydrogen (H), Methane (CH), combustible gases, VOCs, and other toxic or flammable gases, depending on the application and sensor requirement. It provides real-time gas concentration monitoring with visual, audible, and relay alarm outputs, helping users identify gas leaks and hazardous conditions at an early stage. The system is suitable for continuous gas monitoring, leak detection, process safety, plant safety, confined-area monitoring, and emergency alarm applications and can be configured for single-point or multi-point monitoring. Suitable for applications in Oil Refineries, Petrochemical, Chemical, Oil & Gas, Natural Gas, LNG/LPG, Fertilizer, Coal Mining, Power Plants, Iron & Steel, Foundries, Pharmaceutical, Battery Manufacturing, and other industrial environments, the fixed gas monitoring system provides reliable long-term monitoring and supports safer industrial operations.

Industrial-Grade Design and Durability

The ATS-107M is engineered with a sturdy weatherproof casing and durable components, ensuring reliable operation in demanding indoor industrial environments. The compact terminal box and main module design offer easy wall or enclosure mounting, optimizing space without compromising on robust performance. Compliance with safety standards guarantees long-term usage and peace of mind.


Intuitive Operation and User Programmability

Featuring a backlit LCD display and a full array of push button controls-including FN, EN, RESET, and arrow keys-the ATS-107M enables straightforward navigation and user configuration. Manual reset and calibration ensure customizable alarm and monitoring parameters, while easy-to-understand status LEDs deliver immediate system feedback for operational convenience.


Real-Time Monitoring and Safety Assurance

Continuous, real-time ammonia monitoring with advanced electrochemical sensor technology enables rapid detection of hazardous concentrations. Alarm conditions are indicated clearly by main, alarm, and trouble LEDs, dramatically improving safety awareness. Optional audible alarms, relay outputs, and RS-485 communication allow integration with building management or safety systems.

FAQ's of Industrial Gas Monitoring System:


Q: How does the ATS-107M detect ammonia gas in industrial settings?

A: The ATS-107M uses an advanced electrochemical sensor specifically designed to measure ammonia (NH3) concentrations. It continuously monitors air quality, displaying accurate PPM values in real time on its large digital LCD.

Q: What alarm features does the ATS-107M offer for immediate hazard notification?

A: The system includes visual alarms via main, alarm, and trouble LEDs on the front panel. An audible alarm option is also available for enhanced awareness. Alarms activate when ammonia levels exceed programmable thresholds.

Q: When should the ATS-107M be reset, and how is this accomplished?

A: After an alarm event or maintenance, users can reset the device manually using the dedicated RESET button on the control panel, ensuring the system returns to normal monitoring mode.

Q: Where can the ATS-107M be installed for optimal operation?

A: This model is intended for indoor industrial applications, suitable for mounting on walls or within enclosures. Its weatherproof casing helps protect it from environmental influences commonly found in factory or processing settings.

Q: What is the process for calibrating the ATS-107M, and can users perform it?

A: Calibration is user configurable, meaning authorized personnel can follow the simple on-screen prompts to calibrate the sensor, ensuring continued accuracy and reliability.

Q: How does the ATS-107M connect and communicate with other equipment or control systems?

A: The unit offers dedicated sensor ports, RS-485 communication for integration with external systems (including optional data logging), and relay outputs for triggering auxiliary devices like alarms or ventilation controls.

Q: What are the primary benefits of using the ATS-107M in industrial gas monitoring?

A: Benefits include real-time, precise NH3 detection, user-friendly operation, manual reset, robust safety compliance, interface flexibility (RS-485, relay), compact design, and maintenance-free, license-free operation-making it ideal for enhancing workplace safety.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Gas Monitoring Systems Category

Ambient Monitoring Systems

Ambient Monitoring Systems

Price 329500.0 INR / Piece

Minimum Order Quantity : 1 Piece

Screen Resolution : 0.01%

Power Supply : 230 VAC

Special Features : Online Monitoring

Output Formats : RS485 Serial Communication

Industrial Gas Detection System

Industrial Gas Detection System

Price 130500.0 INR / Piece

Minimum Order Quantity : 1 Piece

Screen Resolution : Digital LED numeric display

Power Supply : 230V AC, 50Hz

Special Features : Multichannel detection, digital display, LED indicators for alarm/warn/trouble status, modular channel units

Output Formats : Relay Output, 420mA analog output, RS485 Modbus

Fixed Gas Monitoring System

Fixed Gas Monitoring System

Price 75500.0 INR / Piece

Minimum Order Quantity : 1 Piece

Screen Resolution : 3digit high brightness LED display

Power Supply : 230V AC, 50Hz

Special Features : Multichannel display (up to 4 channels), realtime H2S gas concentration monitoring, individual channel indicators for alarm, warning, and trouble

Output Formats : Analog 420mA, Relay output

Centralized Gas Monitoring System

Centralized Gas Monitoring System

Price 73500.0 INR / Piece

Minimum Order Quantity : 1 Piece

Screen Resolution : Backlit LCD display, 4digit numeric

Power Supply : 230 VAC

Special Features : Multiple gas detection, digital display, audible/visual alarm, trouble and alarm indicators

Output Formats : Relay, RS485 digital output