About Online SO2 Gas Analyzer
Online SO2 Gas Analyzer (Microcontroller based) with sampling systems - Model ATS 208A
Online SO2 Gas Analyzer is used for error free detection of toxic as well as flammable gases in chemical engineering, petroleum processing and in other industries. This instrument can be operated under -5 degree C to 55 degree C operating temperature range. Compact shape, ergonomic look, portable design, accurate dimension and user friendly mechanism are the key characteristics of this Online SO2 Gas Analyzer.
TUV Approved
Application
- Gas turbines
- Power Plants
- Boiler systems - Coal , Oil and gas fired
- Cement & lime manufacture
- Incinerators - domestic, hazardous, clinical and biological waste
Specification:
- Range: 0-2000 PPM
- Power supply: 230V AC
- Digital Output:RS 232
- Auto Sampling:Tube cleaning systems
- Operating Temperature:0-250 Deg C
Real Time Data Connectivity as per CPCB / SPCB Guidelines
Specification :-
| Principle | Electrochemical, TCD (Thermal Conductivity) , NDIR (Non Dispersive Infrared ), Zirconium and Paramagnetic |
| Range | %V/V, % LEL, PPM, Mg/M3 |
| Resolution | 0.1 Unit or 1 Unit (Application based) |
| Sampling Method | Auto Suction |
| Gas Sampling Probe | Dia 8mm SS 316 |
| Display | 320 X 264 Graphic LCD |
| Alarm | Relay Contact NO+NC |
| Anolog Out Put | 4-20mA |
| Digital Out Put | RS 232, RS 485 and Modbus Comminication Protocol |
| Power Source | 230VAC |
| Accuracy | +/2% |
| Response Time | <5 Second |
| Data Storage | 5000 or 10000 |
| Computer Interface | RS 232, USB, RS485 |
| Sensor Life | 2-3 Years |
| Environmental | |
| Temperature | 15degree Celsius |
| Humidity | < 85%RH |
| Atmosphere Pressure | 86-106Kpa |
| Dimension in mm | 430 (W) X 150(H) X 250(D) |
| Weight | 2.5 KG |
| Warranty | One Year |
Technical Details 
Technical Details 
Advanced Emission Monitoring SolutionThis SO2 Gas Analyzer is specifically developed to facilitate continuous emission monitoring in factories and industrial units. Its digital display provides clear and immediate readings, ensuring that users can promptly detect and address any discrepancies in emission levels, thereby supporting regulatory compliance and environmental safety.
Robust Performance in Challenging EnvironmentsWith its capability to operate at temperatures from -5C to +55C and humidity levels below 85%, this analyzer is well-suited for diverse industrial conditions. The durable design also makes it easy to integrate into existing monitoring systems without significant modifications or downtime.
FAQs of Online SO2 Gas Analyzer:
Q: How does the Online SO2 Gas Analyzer operate for emission monitoring in industries?
A: The analyzer continuously measures sulfur dioxide (SO2) levels in industrial emissions using digital detection technology, offering high accuracy with real-time display of results. It assists facilities in consistently tracking emission levels for regulatory adherence.
Q: What are the main benefits of using a digital SO2 analyzer in industrial environments?
A: Utilizing this digital SO2 analyzer provides high measurement accuracy (2%), immediate data visualization, and reliability even in harsh conditions, which collectively help optimize compliance, reduce environmental impact, and ensure operational efficiency.
Q: When should industries deploy this SO2 gas analyzer in their emission monitoring process?
A: Industries should install the SO2 gas analyzer as part of their continuous emission monitoring system, especially where sulfur dioxide emissions require regular tracking for regulatory or safety standards.
Q: Where can this SO2 Gas Analyzer be installed within an industrial facility?
A: Thanks to its compact dimensions (430 x 150 x 250 mm), the analyzer can be conveniently mounted in control rooms, emission stacks, or integrated into sampling lines where emission gases are analyzed.
Q: What is the recommended process for maintaining the SO2 Gas Analyzer?
A: Routine maintenance involves periodic calibration checks, ensuring the analyzer remains within 2% accuracy, and keeping the instrument clean to prevent interference from particulate or condensate buildup.
Q: How does environmental humidity or temperature affect the analyzers performance?
A: The analyzer is designed to function accurately at humidity levels below 85% RH and in ambient temperatures from -5C to +55C, ensuring consistent operation across varying industrial environments.