About Trace Oxygen Measurement System
The Portable Trace Oxygen Analyser is a compact and reliable gas analysis instrument designed for accurate measurement of very low concentrations of Oxygen (O) in industrial, process, and specialty gas applications. It is suitable for trace oxygen measurement where precise monitoring of oxygen levels is important for gas purity control, process monitoring, quality assurance, inerting, purging, leak detection, and operational safety. Depending on the configuration, the analyser can provide measurement across trace oxygen ranges from PPM levels to higher oxygen concentrations, making it suitable for a wide range of gas analysis requirements. Its portable design enables convenient on-site testing, routine inspection, commissioning, maintenance, troubleshooting, and verification at different sampling points. The Portable Trace Oxygen Analyser is suitable for applications involving Nitrogen (N), Hydrogen (H), Argon (Ar), Helium (He), industrial gases, specialty gases, gas cylinders, gas pipelines, laboratories, chemical processing, petrochemical plants, power generation, metal processing, and other industries requiring accurate trace oxygen monitoring. It provides a practical solution for field-based oxygen purity and low-level oxygen concentration measurement.
Advanced Sensor TechnologyUtilizing electrochemical sensors, the ATS-208A measures trace oxygen concentrations with remarkable accuracy (2% of reading). The microprocessor-based control mode ensures reliable and consistent performance, making it suitable for monitoring industrial gases where precise oxygen measurement is critical.
Configurable and User-Friendly FeaturesThe system's calibration process is user programmable for optimal flexibility, allowing operators to tailor settings as needed. The digital backlit LCD display provides easy readability, and display units can be toggled between PPM and percentage. Its alarm relay output and automatic zero calibration further enhance usability and safety.
Efficient Operation and Robust BuildWith a warm-up time of less than 60 seconds and a T90 response time of under 10 seconds, the ATS-208A provides fast, continuous measurements. The stainless steel enclosure ensures durability, while its compact, table-top design makes it easy to integrate into a variety of industrial setups.
FAQ's of Trace Oxygen Measurement System:
Q: How does the ATS-208A Trace Oxygen Measurement System work?
A: The ATS-208A utilizes electrochemical sensor technology for measuring trace oxygen concentrations in industrial gases. Sample gas flows through the sensor at 200-500 mL/min, and oxygen levels are detected and displayed digitally, allowing real-time monitoring.
Q: What are the main benefits of using this system for trace oxygen monitoring?
A: This system offers rapid response times (T90 <10 seconds), high accuracy (2% of reading), user-programmable calibration, and automatic zero calibration. Its alarm relay output enhances safety, and its robust stainless steel enclosure ensures durability in industrial environments.
Q: When should calibration be performed for optimal accuracy?
A: Calibration can be performed at user-defined intervals to maintain measurement accuracy, especially when changing gas types or after extended periods of operation. The user-programmable feature allows operators to tailor the calibration schedule to their requirements.
Q: Where is the ATS-208A typically installed or used?
A: It is commonly installed in industrial settings such as gas processing plants, labs, and manufacturing facilities. With table-top mounting and IP20 protection, the system is suitable for environments demanding continuous online measurement of trace oxygen levels.
Q: What is the process for setting alarm thresholds and outputs?
A: Alarm thresholds can be configured through the system's microprocessor controls, allowing users to set oxygen concentration levels to trigger the relay output. This ensures timely alerts and supports effective process control and safety management.
Q: How is the display resolution and units selection handled?
A: The digital backlit LCD offers a 12-bit resolution, providing clear readings down to 1 ppm. Users can select display units as either PPM or % according to their monitoring needs, facilitating easy interpretation and reporting.
Q: Can the ATS-208A handle varying gas pressures and humidity levels?
A: Yes, the system operates effectively within a gas pressure range of 0.5 to 5 bar and humidity levels of 0-99% RH (non-condensing). It supports a wide range of operating conditions (0C to 50C), ensuring reliable performance in diverse environments.