Tri Gas Monitoring Instrument Specification

  • Temperature
  • 0-50C
  • Interface Type
  • RS232/USB (optional)
  • Measuring Range
  • O2 (0-25%), CO2 (0-100%), N2 (By calculation)
  • Automation Grade
  • Automatic
  • Humidity
  • 10-90% RH (Non-Condensing)
  • Application
  • Monitoring and Analyzing O2, CO2 & N2 concentrations in gas mixtures
  • Equipment Type
  • Tri-Gas Monitoring Instrument
  • Mounting Type
  • Bench-Top
  • Resolution
  • O2: 0.01%; CO2: 0.1%
  • Response Time
  • Less than 15 seconds
  • Number of Specimens
  • Single Sample Input
  • Power Supply
  • 230V AC, 50 Hz
  • Gas Pressure
  • 0.1-6 bar
  • Port Size
  • 1/4 inch NPT
  • Operating Voltage
  • 230V AC, 50Hz
  • Test Range
  • O2: 0-25%, CO2: 0-100%, N2: By Difference
  • Accuracy
  • O2: 0.3%; CO2: 1% of FS
  • Features
  • Portable, Digital Display, Adjustable Flow Meter, Alarm Indication, Stainless Steel Housing
  • Frequency
  • 50 Hz
  • Display Type
  • Digital LCD with Backlight
  • Usage
  • Industrial Gas Analysis, Controlled Atmosphere Packaging, Lab Research
  • Machine Weight
  • Approx. 5 kg
  • Control Mode
  • Microcontroller-Based
  • Alarm System
  • Visual and Audible Alarm
  • Analyzer Model
  • ATS-203A
  • Protection Class
  • IP20
  • Language Support
  • English (Others on Request)
  • Calibration
  • User Programmable, Standard Gases Required
  • Sampling Method
  • Manual or Automatic Sample Draw
  • Data Logging
  • Built-in Memory, Downloadable via USB
  • Enclosure Material
  • Stainless Steel (SS-304)
  • Warm-Up Time
  • <2 minutes
  • Gas Connection
  • Push-Fit or NPT (Customizable)
  • Dimensions (LxWxH)
  • 350 x 260 x 160 mm
 
 

About Tri Gas Monitoring Instrument

The Tri Gas Analyser is a portable and reliable gas analysis instrument designed for accurate measurement and monitoring of gas composition in power generation and other industrial applications. It is particularly suitable for measuring Hydrogen (H), Air, and Carbon Dioxide (CO) during generator filling, purging, shutdown, startup, and normal operating conditions, helping users monitor gas purity and ensure safe and efficient operation. The analyser uses a reliable gas measurement system with temperature compensation for stable and accurate readings and can be configured with suitable sampling components for convenient field analysis. Its portable design makes it suitable for generator gas purity testing, hydrogen cooling system monitoring, gas replacement and purging operations, maintenance, commissioning, troubleshooting, and routine inspection. The Tri Gas Analyser can be used in power plants, electrical power generation facilities, turbine-generator systems, industrial plants, hydrogen-cooled generators, and other applications requiring reliable measurement of hydrogen, air, and carbon dioxide gas composition. It provides a practical solution for on-site gas analysis, helping operators verify gas purity, monitor generator conditions, and support safe and efficient plant operation.

Advanced Tri-Gas Analysis for Industrial Applications

The ATS-203A Tri Gas Monitoring Instrument is engineered to deliver precise O2, CO2, and N2 measurements in various gas mixes. Its robust stainless steel body and rapid response ensure high durability and efficiency for industries involved in gas analysis, packaging, and laboratory research. Thanks to its both manual and automatic sampling system, the instrument adapts easily to different operational needs, providing flexibility across multiple use cases.


User-Friendly Operation and Data Management

Equipped with a digital LCD and intuitive control, the ATS-203A simplifies measurement tasks. Built-in data logging with easy USB downloads streamlines record management, while user-programmable calibration enhances operational independence. The device's safety features-such as visual and audible alarms-allow for prompt response to abnormalities, ensuring secure working conditions in critical environments.

FAQ's of Tri Gas Monitoring Instrument:


Q: How does the ATS-203A Tri Gas Monitoring Instrument perform gas sampling?

A: The ATS-203A supports both manual and automatic sample draw modes, allowing users to choose the most suitable method for their specific application or workflow. This flexibility is ideal for industrial and laboratory environments requiring precise control or consistency.

Q: What is the process for calibrating the ATS-203A Analyzer?

A: Calibration is user programmable on the ATS-203A. Users simply connect standard calibration gases as required and follow on-screen prompts on the LCD display. This ensures continued accuracy for O2, CO2, and N2 measurements.

Q: When should data be downloaded from the built-in memory, and how is it accessed?

A: Data logging occurs automatically, and retrieval is straightforward via the built-in USB port. Users should download data as needed for record-keeping, analysis, or compliance purposes. File access and transfer are managed easily from the instrument's digital interface.

Q: Where can the ATS-203A be effectively installed or used?

A: Designed as a bench-top instrument, the ATS-203A is suitable for use in industrial facilities, laboratories, or production lines requiring monitoring and analysis of gas mixtures. Its stainless steel housing and compact form make it adaptable to many controlled environments.

Q: What are the major benefits of using the ATS-203A for gas analysis?

A: This analyzer offers precise readings (O2: 0.01% resolution, CO2: 0.1%), swift response time (<15 seconds), and robust construction. It enhances operational safety via visual and audible alarms and supports efficient data management, all contributing to reliable and streamlined gas monitoring.

Q: How does the alarm system function in the ATS-203A Tri Gas Monitoring Instrument?

A: The instrument's alarm system includes both visual and audible alerts, which are triggered if set gas concentration thresholds are breached. This ensures operators are immediately notified of abnormal readings, supporting prompt corrective action.

Q: What is the typical warm-up and response time of the ATS-203A?

A: The warm-up time for the ATS-203A is less than two minutes, and it provides gas concentration readings in under 15 seconds, facilitating quick and efficient monitoring cycles for routine and critical analyses.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Gas Analysers Category

Portable Trace Oxygen Monitoring Equipment

Portable Trace Oxygen Monitoring Equipment

Price 350500.0 INR / Piece

Minimum Order Quantity : 1 Piece

Temperature : 0C to 50C

Control Mode : Microprocessor Based

Machine Weight : Approx. 1.8 kg

Response Time : <10 seconds

Biogas Testing Equipment

Biogas Testing Equipment

Price 855500.0 INR / Piece

Minimum Order Quantity : 1 Piece

Temperature : 0C to 50C

Control Mode : Automatic

Machine Weight : 35 kg

Response Time : <10 Seconds

Tri Gas Monitoring Equipment

Tri Gas Monitoring Equipment

Price 450500.0 INR / Piece

Minimum Order Quantity : 1 Piece

Temperature : 0C 50C

Control Mode : Automatic

Machine Weight : 8 kg

Response Time : <10 seconds

Gas Measurement Devices

Gas Measurement Devices

Price 32500.0 INR / Unit

Minimum Order Quantity : 1 Unit

Temperature : 15 Celsius (oC)

Control Mode : Manual

Machine Weight : 500 Gram (g)

Response Time : 10 Seconds at 95% variation Seconds