WhatsApp Chat with us
Gas Detection Monitoring System
Gas Detection Monitoring System
Gas Detection Monitoring System
Gas Detection Monitoring System
Gas Detection Monitoring System
Gas Detection Monitoring System
Gas Detection Monitoring System
Gas Detection Monitoring System

Gas Detection Monitoring System

Price 61500.0 INR/ Piece

MOQ : 1 Piece

Gas Detection Monitoring System Specification

  • Mounting Type
  • Wall mounting, enclosure
  • Standard
  • Industrial grade, Model ATS-107M
  • Interface
  • RS-485, Relay, Sensor interface
  • License Free
  • Yes
  • Connectivity Type
  • RS-485, Relay contacts
  • Operating Mode
  • Continuous monitoring
  • Size
  • Compact enclosure (size not specified)
  • Technology
  • Microcontroller-based gas detection
  • Special Features
  • Multiple status indication (Main, Alarm, Trouble), Digital display, Terminal box for sensor, relay, communication, and power
  • Application
  • Industrial gas monitoring, Ammonia (NH3) detection
  • Screen Resolution
  • High contrast LCD, numeric display
  • Power Supply
  • 230 VAC
  • Output Formats
  • RS-485 communication, Relay output
  • Functional Buttons
  • FN, EN, Arrow keys
  • Model Number
  • ATS-107M
  • Display Type
  • Backlit LCD numeric display
  • Enclosure Protection
  • Transparent polycarbonate cover
  • Reset Function
  • Physical reset button
  • Alarm Indication
  • Visual LED indicators
  • Measurement Units
  • PPM for ammonia (NH3)
  • Sensor Input
  • Dedicated sensor terminal
  • Terminal Box Connectivity
  • Sensor, RS-485, Relay, AC Power
 

Gas Detection Monitoring System Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Delivery Time
  • 5-7 Days
 

About Gas Detection Monitoring System

The Fixed / Continuous Gas Monitoring System is an industrial gas detection and monitoring solution designed for the continuous measurement of hazardous, toxic, combustible, and flammable gases in industrial and commercial environments. The system can be configured with multiple gas sensor transmitters and control units to continuously monitor gases such as Oxygen (O), Hydrogen Sulfide (HS), Carbon Monoxide (CO), Sulfur Dioxide (SO), Hydrogen (H), Methane (CH), combustible gases, VOCs, and other toxic or flammable gases, depending on the application and sensor requirement. It provides real-time gas concentration monitoring with visual, audible, and relay alarm outputs, helping users identify gas leaks and hazardous conditions at an early stage. The system is suitable for continuous gas monitoring, leak detection, process safety, plant safety, confined-area monitoring, and emergency alarm applications and can be configured for single-point or multi-point monitoring. Suitable for applications in Oil Refineries, Petrochemical, Chemical, Oil & Gas, Natural Gas, LNG/LPG, Fertilizer, Coal Mining, Power Plants, Iron & Steel, Foundries, Pharmaceutical, Battery Manufacturing, and other industrial environments, the fixed gas monitoring system provides reliable long-term monitoring and supports safer industrial operations.

Advanced Safety for Industrial Environments

Engineered for ammonia detection, the ATS-107M delivers high-precision monitoring in environments where gas safety is paramount. Users benefit from real-time data displayed on a bright LCD, while immediate visual alerts ensure prompt response to hazardous levels. The robust enclosure and intuitive controls make it an essential tool for operational safety in manufacturing and processing plants.


Reliable Connectivity and Integration

With a dedicated terminal box supporting sensor input, RS-485 communication, relay output, and AC power, this system enables seamless integration with facility management and automation. Its flexible connectivity supports scalable deployment while maintaining industrial compliance and consistent monitoring.


User-Friendly Design and Continuous Operation

The ATS-107M is designed for ease of use, featuring tactile arrow keys, functional buttons, and a clear numeric display. The physical reset button allows quick recovery from alarm states, ensuring minimal downtime. Continuous 24/7 monitoring guarantees early detection, helping prevent safety incidents and equipment damage.

FAQ's of Gas Detection Monitoring System:


Q: How does the ATS-107M Gas Detection Monitoring System detect ammonia (NH3) concentrations?

A: The ATS-107M utilizes a dedicated gas sensor input to detect ammonia (NH3) and measures concentrations in parts per million (PPM). The microcontroller-based technology continuously monitors the environment, providing real-time readings and alerts for prompt safety management.

Q: What visual indications and alerts are provided by the system?

A: The monitoring system features visual LED indicators to signify main operation, alarms, and trouble status. High-contrast, backlit numeric LCD adds clarity, ensuring users can instantly recognize dangerous ammonia levels or system issues.

Q: When should I use the physical reset button?

A: The physical reset button should be used after an alarm has been triggered or to acknowledge trouble status. This helps restore the system to normal monitoring mode after issues have been resolved or attended to.

Q: Where can the ATS-107M be installed within an industrial facility?

A: The ATS-107M is designed for wall-mounted installation in industrial settings where ammonia gas monitoring is required. Its compact enclosure and transparent polycarbonate cover provide durability and visibility in manufacturing plants, process areas, and storage rooms.

Q: What is the process for integrating this system with other equipment or control systems?

A: Integration is straightforward using the terminal box, which provides sensor inputs, RS-485 communication, relay outputs, and AC power connections. This enables the system to interface with existing automation, alarm panels, and monitoring networks within the facility.

Q: How is data from the ATS-107M displayed and communicated?

A: Measurement data and status updates are prominently displayed on a backlit LCD numeric screen. For remote monitoring or system integration, RS-485 communication protocol and relay outputs transmit key data and alerts to external control and supervisory systems.

Q: What are the key benefits of using the ATS-107M Gas Detection Monitoring System in industrial applications?

A: The ATS-107M offers continuous, reliable ammonia detection with user-friendly operation, robust alarm indication, and flexible integration options. These features help maintain workplace safety, ensure regulatory compliance, and minimize the risk of gas-related incidents or equipment failures.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Gas Monitoring Systems Category

Fixed Gas Detection System

Fixed Gas Detection System

Price 110500.0 INR / Piece

Minimum Order Quantity : 1 Piece

Power Supply : 230V AC (standard), 24V DC (optional)

Operating Mode : Continuous, automatic monitoring

Connectivity Type : Wired, RS485 MODBUS (digital), Analog output

Application : Industrial environments, hazardous area gas detection, manufacturing plants

Fixed Gas Monitoring System

Fixed Gas Monitoring System

Price 68500.0 INR / Piece

Minimum Order Quantity : 1 Piece

Power Supply : 230 VAC

Operating Mode : Continuous monitoring

Connectivity Type : Wired (RS485, relay output)

Application : Industrial gas monitoring, ammonia (NH3) detection, safety compliance in hazardous environments

Centralized Gas Detection System

Centralized Gas Detection System

Price 150500.0 INR / Piece

Minimum Order Quantity : 1 Piece

Power Supply : 230V AC / 24V DC (as per model)

Operating Mode : Continuous Monitoring, Fault & Alarm Modes

Connectivity Type : Wired Connection to Remote Sensors, RS485 Option

Application : Industrial Plants, Chemical Industries, Oil & Gas Facilities, Petrochemical Plants, Refineries, Environmental Monitoring

Fixed Gas Detection System for Industry

Fixed Gas Detection System for Industry

Price 65000.0 INR / Piece

Minimum Order Quantity : 1 Piece

Power Supply : 230 VAC

Operating Mode : Continuous monitoring

Connectivity Type : Wired

Application : Industrial fixed gas monitoring, ammonia gas (NH3) detection