About Online Continuous Emissions Monitoring Systems (OCEMS)
Online Continuous Emission Monitoring Systems (OCEMS)
- Model ATS 208A
- Approval Certificate : TUV
- With Remote calibration facility
Applied Techno Systems is Indigenous manufacturer of CEMS Model ATS 208A which includes Gas Analyser, Gas Sampling Systems, Tempreture , flow & Opacity dust Monitoring Systems with real time data transmission Systems to CPCB & SPCB.
Applied Continuous Emission Montoring CEMS fullfill the environmental regulatory compliance of various industrieal sources of air pollutant.
Features
- Microcontroller based embedded intelligent instruments
- Continuous Monitoring of CO2 ,CH4, CO, O2, SO2, NOX (NO NO2), H2, H2S, N2
- Duel wavelength Infra red sensor for Long terms accuracy and stability
- Long Life Electrochemical sensor
- Six Gas Analysis in Single Analyser
- Multi Parameter Single 320 X 240 Graphics LCD Display
- Self diagnostic & Self integrity check
- RS 232/RS 485 and USB Computer Interface
- Excellent low level capability for NOX and SO2 Measurement
- For most of the application sample gas is cooled and dried inside the sampling conditioning systems to avoid the Heated Sample Line.
- Analog 4-20mA output for each gas
- Software solutions for Gas Analysis
- Web Based Real time data transfer with GSM/GPRS Technology
Specification :-
| Principle | Electrochemical, TCD (Thermal Conductivity) , NDIR (Non Dispersive Infrared ), Zirconium and Paramagnetic |
| Range | %V/V, % LEL, PPM, Mg/M3 |
| Resolution | 0.1 Unit or 1 Unit (Application based) |
| Sampling Method | Auto Suction |
| Gas Sampling Probe | Dia 8mm SS 316 |
| Display | 320 X 264 Graphic LCD |
| Alarm | Relay Contact NO+NC |
| Anolog Out Put | 4-20mA |
| Digital Out Put | RS 232, RS 485 and Modbus Comminication Protocol |
| Power Source | 230VAC |
| Accuracy | +/2% |
| Response Time | <5 Second |
| Data Storage | 5000 or 10000 |
| Computer Interface | RS 232, USB, RS485 |
| Sensor Life | 2-3 Years |
| Environmental | |
| Temperature | 15degree Celsius |
| Humidity | < 85%RH |
| Atmosphere Pressure | 86-106Kpa |
| Dimension in mm | 430 (W) X 150(H) X 250(D) |
| Weight | 2.5 KG |
| Warranty | One Year |
High-Accuracy Digital MonitoringOur OCEMS devices offer an impressive 2% accuracy, ensuring minimal deviations and trustworthy data for continuous emission tracking. The digital interface allows for straightforward monitoring and data interpretation, supporting informed decision-making and regulatory compliance.
Rugged and Versatile for Industrial UseDesigned to withstand harsh industrial environments, our OCEMS functions efficiently in temperatures ranging from -5C to 55C and humidity levels below 85% RH. Its durability and adaptability make it a reliable choice for emission monitoring in diverse sectors.
Comprehensive Support Across IndiaWe support customers throughout India, providing end-to-end services as manufacturers, exporters, importers, and solution providers. Our expertise covers installation, calibration, and after-sales support, ensuring an uninterrupted monitoring process and timely adherence to emission regulations.
FAQs of Online Continuous Emissions Monitoring Systems (OCEMS):
Q: How does an Online Continuous Emissions Monitoring System work?
A: OCEMS continuously measures and analyzes emissions from industrial processes using sensors and analyzers, relaying real-time data to a digital display unit. This allows for consistent compliance monitoring with environmental standards and swift action if discrepancies arise.
Q: What are the main benefits of using OCEMS in industrial operations?
A: The key benefits include real-time monitoring, high accuracy (2%), compliance with regulatory standards, improved environmental responsibility, and operational transparency. The systems digital display simplifies data interpretation and supports timely decision-making.
Q: When should OCEMS be installed in an industrial facility?
A: OCEMS should be installed before initiating operations that emit regulated pollutants or when local environmental authorities require continuous emission data submission. Early installation ensures compliance from the start and prevents potential regulatory penalties.
Q: Where in India do you provide installation and after-sales services for OCEMS?
A: We offer installation, calibration, and service support across India, catering to industries nationwide as an exporter, importer, manufacturer, supplier, and service provider. Our team ensures prompt and effective assistance regardless of location.
Q: What is the process for procuring an OCEMS and getting it operational?
A: Customers can contact us directly to discuss specific requirements. We assist with system selection, customization, shipping, installation, calibration, and staff training. Post-installation, we provide maintenance and technical support to ensure optimal functionality.
Q: How should OCEMS be maintained for best performance and accuracy?
A: Regular maintenance involves scheduled calibration, routine inspection of sensors and analyzers, and ensuring that the system is kept within the specified temperature and humidity range. Our support team offers periodic servicing to maintain accuracy and reliability.